Part Number Hot Search : 
C686M 4057A T10B110B DS2175N 2K060 MSP10C SFH7221 800M25V1
Product Description
Full Text Search
 

To Download C9404MC Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MODULE
Mini-spectrometer TG series
C9404MC, C9405MC
Integrating optical system, image sensor and circuit
HAMAMATSU TG series mini-spectrometers are polychromators integrated with optical elements and an image sensor. Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the built-in image sensor is output from the USB port to a PC for data acquisition. C9404MC and C9405MC are palmtop-size units and operate on USB bus power. Two models are available to cover different spectral ranges: C9404MC (TG-UV-MOS) and C9405MC (TG-SWNIR-MOS). The TG series comes with sample software, device driver and DLL that let you easily set measurement conditions and acquire, save and graphically display the spectrum data.
Features
Applications
C9404MC (TG-UV-MOS) l High throughput due to transmission grating made of quartz l Highly accurate optical characteristics l Fluorescence measurement l Tooth decay analysis l No external power supply required: Uses USB bus power l UV light source testing l Compact design for easy assembly C9405MC (TG-SWNIR-MOS) l Wavelength conversion factor *1 is recorded in internal l Detection of saccharic acids in foods memory l Taste analyzers l LED testing *1: A conversion factor for converting the image sensor pixel number into a wavelength is recorded in the module. A calculation factor for converting the A/D converted count into the input light intensity is not provided.
n
Mini-spectrometer line-up
Type No. Type
TM-UV/VIS-CCD High sensitivity TM-UV/VIS-CCD High resolution
Spectral response range (nm)
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Spectral resolution Max. (nm)
Image sensor
C10082CA C10082CAH
6
200 to 800
1* 6 8 (=320 to 900 nm)
Back-thinned type CCD image sensor
TM series
C10082MD C10083CA C10083CAH C10083MD C9404CA
TM-UV/VIS-MOS Wide dynamic range TM-VIS/NIR-CCD High sensitivity TM-VIS/NIR-CCD
CMOS linear image sensor
High resolution
TM-VIS/NIR-MOS Wide dynamic range TG-UV-CCD
320 to 1000
Back-thinned type CCD image sensor 1* (=320 to 900 nm)
8 3
200 to 400
CMOS linear image sensor Back-thinned type CCD image sensor Back-thinned type CCD image sensor CMOS linear image sensor
High sensitivity
TG-UV-CCD
TG series
C9404CAH
C9404MC C9405CA C9405MC C9406GC C9913GC C9914GB C9407MA
* Typ.
High resolution
TG-UV-MOS
1*
3
Wide dynamic range
TG-SWNIR-CCD High sensitivity
500 to 1100
TG-SWNIR-MOS Wide dynamic range TG-NIR
Back-thinned type 5 (=550 to 900 nm) CCD image sensor
5 (=550 to 1100 nm) 7
900 to 1700
NMOS linear image sensor
TG series
Non-cooled type
TG-cooled NIR-I
Low noise (cooled type)
TG-cooled NIR-II
7
1100 to 2200
InGaAs linear image sensor
Low noise (cooled type)
8 9
CMOS linear image sensor
RC series
RC-VIS-MOS
Spectrometer module
340 to 780
OEM model
Type No.
Type
Spectral response range (nm)
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Spectral resolution Max. (nm)
Image sensor
CMOS linear image sensor
RC series
RC-VIS-MOS
C9409MA
Spectrometer head
340 to 780
9
1
Mini-spectrometer TG series
s Specifications
Parameter Number of pixels Spectral response range Spectral resolution Max. (Spectral response half width) *2 Wavelength reproducibility *4 Wavelength temperature dependence Spectral stray light *2, *5 Broadband stray light *2, *6 Slit *7 A/D conversion Integration time Optical NA *8 TG-UV-MOS C9404MC 512 200 to 400 3 0.1 0.02 -35 -27 140 (H) x 500 (V) 16 5 to 10000
C9404MC, C9405MC
TG-SW NIR-MOS C9405MC 500 to 1100 5 *3 0.2 -35 -27 70 (H) x 2500 (V)
Unit pixels nm nm nm nm/C dB dB m bit ms -
0.11 0.22 CMOS linear image sensor NMOS linear image sensor Image sensor (S8378-512Q) (S8381-512Q) Connector for optical fiber SMA905D Interface USB1.1 Current consumption *9 100 100 mA Operating temperature *10 +5 to +40 C Storage temperature -20 to +70 C Dimensions 40 (W ) x 106 (D) x 86 (H) mm *2: Depends on the slit opening. Values were measured with the slit opening listed in the table. *3: =550 to 1100 nm *4: Measured under constant light input conditions. *5: W hen monochromatic light of the following wavelengths is input, spectral stray light is defined as the ratio of the count measured at the input wavelength, to the count measured in a region of the input wavelength 20 nm (C9404MC) or 40 nm (C9405MC). C9404MC: 300 nm, C9405MC: 800 nm *6: This is the ratio of the transmittance measured with light passing through the following optical filters to the transmittance measured in the blocking region. C9404MC: W G320, C9405MC: RG850 *7: Entrance slit aperture size *8: Numerical aperture (solid angle) *9: USB bus power *10: No condensation
s Optical component layout
TG series mini-spectrometers use a transmission holographic grating made of quartz and precision optical components arranged on a rugged optical base, making it possible to deliver high throughput and highly accurate optical characteristics.
FOCUSING LENS TRANSMISSION GRATING IMAGE SENSOR COLLIMATING LENS
s Connection example (transmission light measurement)
Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the built-in image sensor is output through the USB port to a PC for data acquisition. There are no moving parts inside the unit so stable measurements are obtained at all times. An optical fiber that guides light input from external sources allows a flexible measurement setup.
PC
ENTRANCE SLIT
USB CABLE UV-VIS FIBER LIGHT SOURCE (Deuterium lamp and Halogen lamp) L10290
MINI-SPECTROMETER
KACCC0256EA
QUARTZ CELL (For holding liquid sample) FIBER
KACCC0257EB
2
Mini-spectrometer TG series
s Dedicated software package (supplied with unit)
C9404MC, C9405MC
Installing the dedicated software package (containing sample software, device driver, DLL)*11 into your PC allows running the following basic tasks: * Measurement data acquisition and save * Measurement condition setup * Module information acquisition (wavelength conversion factor, polychromator type, etc.) * Graphic display * Arithmetic operation Pixel number to wavelength conversion Dark subtraction Comparison calculation with reference data (transmittance, reflectance) Gaussian approximation (peak position and count, FWHM) Note: Two or more mini-spectrometers can be connected and used with one PC simultaneously. *11: Compatible OS: Microsoft Windows Professional Edition 2000 (SP3 or later) and XP (SP1a or later) Device driver and DLL for controlling hardware are also provided. You can develop your own measurement programs by using a software development environment that includes Microsoft Visual C++ and Visual Basic.*12 The DLL provides functions such as USB port open/close, measurement condition setup, measurement data and module information acquisition. *12: Operation of the device driver and DLL has been verified only with Microsoft Visual C++(R) and Visual Basic(R). Microsoft Visual C++ and Microsoft Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the United States.
s Measurement examples
(1) Transmittance measurement Transmittance of 1 mm thick optical window plate was measured with C9404MC (TG-UV-MOS). * Measurement value
40000
(2) Reflectance measurement Spectral reflectance of reflecting mirror was measured with C9405MC (TG-SWNIR-MOS). * Measurement value
40000
REFERENCE LIGHT 30000 30000
REFERENCE LIGHT
A/D COUNT
20000
A/D COUNT
20000
10000
REFLECTED LIGHT TRANSMITTED LIGHT 10000
0 200
250
300
350
400
0 500
600
700
800
900
1000
1100
WAVELENGTH (nm)
KACCB0096EA
WAVELENGTH (nm)
KACCB0098EA
* Calculation result
100
* Calculation result
100
TRANSMITTANCE RATE (%)
80
80
REFLECTANCE (%)
60
60
40
40
20
20
0 200
250
300
350
400
0 500
600
700
800
900
1000
1100
WAVELENGTH (nm)
KACCB0097EA
WAVELENGTH (nm)
KACCB0099EA
3
Mini-spectrometer TG series
(3) Line spectrum measurement Line spectra from low-pressure mercury lamp were measured with C9404MC (TG-UV-MOS).
100000
C9404MC, C9405MC
10000
A/D COUNT (log)
1000
100
10 200
250
300
350
400
WAVELENGTH (nm)
KACCB0081EA
s Dimensional outline (unit: mm)
40.0
106
KACCA0146EA
s Accessories
* USB cable * Dedicated software (sample software, device driver, DLL)
s Options (sold separately)
Optical fibers for light input Type. No Product name Fiber for UV/visible range A9762-01 (resistance to UV) Fiber for visible/ A9763-01 near infrared range Applicable mini-spectrometer C9404MC (TG-UV-MOS) C9405MC (TG-SWNIR-MOS) Specification Core diameter 600 m, N.A.=0.22, length 1.5 m, connectorized SMA905D at both ends
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. (c)2007 Hamamatsu Photonics K.K.
HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184, www.hamamatsu.com
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P.O.Box 6910, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 08152-3750, Fax: (49) 08152-2658 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Smidesvagen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741 Cat. No. KACC1006E09
86
4
Apr. 2007 DN


▲Up To Search▲   

 
Price & Availability of C9404MC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X